Processor / System Bus |
2 x Socket P (LGA 3647) per Node |
|
1st and 2nd Gen Xeon Scalable Processor Family (165W) |
|
*Refer to support page for more information |
|
UPI (10.4 GT/s) |
Generation |
E9 |
Core Logic |
Intel Lewisburg PCH C621 |
【Memory】 |
|
Total Slots |
12 (6-channel per CPU, 6 DIMM per CPU) per Node |
Capacity |
Maximum up to 1536GB RDIMM |
Memory Type |
DDR4 2933/2666/2400 /2133 RDIMM |
|
DDR4 2933/2666/2400 /2133 LRDIMM |
|
DDR4 2933/2666/2400 /2133 LR-DIMM 3DS |
Memory Size |
128GB, 64GB, 32GB, 16GB, 8GB RDIMM/LRDIMM/LR-DIMM 3DS |
|
* Refer to support page for more information |
【Expansion Slots】 |
|
Per Node |
1 x PCI-E x16 (Gen3 x16 link), LP, HL (from CPU1) |
|
1 x OCP 2.0 Mezzanine (Gen3 x16 link) (from CPU1) |
Storage |
per Node |
SAS/SATA Controller |
Onboard LSI 3008 8-port SAS 12G Controller |
HDD Bays |
8 x 2.5" Hot-swap Storage Bays(All Support SATA/SAS/NVMe) |
|
* each node could control 2 drives. |
|
** CPU2 is necessary for the function of front hot-swap bays. |
Networking |
per Node |
|
2 x Dual Port Intel I350-AM2 Gigabit LAN controller + 1 x Mgmt LAN |
Graphic |
Aspeed AST2500 with 64MB VRAM |
Front I/O Ports |
N/A |
Rear I/O Ports |
<Per Node> 2 x USB 3.0 ports、1 x VGA port、2 x RJ-45 GbE LAN ports、1 x RJ-45 Management port |
Switch/LED |
<Per Node><Rear> - 1 x Power Switch/LED、- 1 x Q-Code/Port 80 LED |
|
<Front> - 1 x Power Switch/LED、- 1 x Location Switch/LED、- 1 x Message LED、- 2 x LAN LED |
OS Support |
Windows Server 2016、RedHat Enterprise Linux、SuSE Linux Enterprise Server、CentOS、Ubuntu、VMware |
Management Solution |
ASUS Control Center |
|
ASMB9-iKVM for KVM-over-IP |
Regulatory Compliance |
BSMI, CE, FCC(Class A) |
Dimensions |
800 x 444 x 88mm |
|
31.5" x 17.48" x 3.46" |
Form Factor |
2U |
Weight |
<Net Weight> 39 Kg <Gross Weight> 43 Kg |
Power Supply |
1+1 Redundant 1600/2200W 80 PLUS Platinum Power Supply |
|
<Rating> 200-240 Vac, 9.5A (for each inlet), 47-63Hz, Class I |
Environment |
<Operation temperature> 10℃ ~ 35℃ |
|
<Non operation temperature> -40℃ ~ 70℃ |
|
<Non operation humidity> 20% ~ 90% ( Non condensing) |
Note |
1. If NVMe SSD is equipped, Intel VROC function could be enabled by VROC Hardware Key. |
|
2. For the full function of the system, please install both CPUs on each node. |